Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Braz. j. phys. ther. (Impr.) ; 16(4): 268-274, Jul.-Aug. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-645494

ABSTRACT

CONTEXTUALIZAÇÃO: O teste da ponte com extensão unilateral do joelho avalia a estabilidade de tronco e pelve. A avaliação dessa estabilidade pode contribuir para o entendimento da ocorrência de lesões musculoesqueléticas. OBJETIVOS: Investigar a confiabilidade intra e interexaminador de uma análise qualitativa e a confiabilidade intrateste de uma análise quantitativa do alinhamento pélvico no plano transverso durante o teste da ponte com extensão unilateral do joelho. MÉTODO: Foram avaliados 30 participantes (24,73±4,24 anos). A análise qualitativa foi realizada pelo julgamento do alinhamento pélvico no plano transverso por dois examinadores, e sua confiabilidade determinada pelo Coeficiente Kappa Ponderado (k w). A análise quantitativa foi realizada pela medida do maior ângulo de desalinhamento pélvico no plano transverso e a confiabilidade determinada pelo Coeficiente de Correlação Intraclasse (CCI); pela análise da mudança na média dos dados, utilizando-se o intervalo de confiança de 95% da média da diferença (95%IC ) e método de Bland-Altman; pelo dimensionamento da variabilidade entre medidas, considerando-se o erro-padrão da medida combinado (EPM) e coeficiente de variação do erro típico (CV ET). Além disso, verificou-se a mudança mínima detectável (MMD95). RESULTADOS: A confiabilidade intraexaminador variou de razoável a moderada (k w=0,32-0,58) e a confiabilidade interexaminador foi substancial (k w=0,80). A confiabilidade intrateste foi excelente (CCI=0,82) e apresentou o IC95% de -0,51º a 1,99º, EPM de 2,38º e o CV ET de 28,75%. O MMD95 foi de 6,59º. CONCLUSÕES: O índice de confiabilidade interexaminador foi superior ao intraexaminador, a confiabilidade intrateste foi excelente e não apresentou erro sistemático e aleatório.


BACKGROUND: The bridge test with unilateral knee extension evaluates the stability of the trunk and pelvis. The evaluation of this stability can contribute to the understanding of the occurrence of musculoskeletal injuries. OBJECTIVES: To investigate the intra- and inter-rater reliability of a qualitative analysis and intra-test reliability of a quantitative analysis of transverse plane pelvic alignment during the bridge test with unilateral knee extension. METHOD: Thirty participants (24.73±4.24 years old) were tested. The qualitative analysis was conducted by asking two raters to judge the transverse plane pelvic alignment and its reliability was assessed with the weighted kappa coefficient (k w). The quantitative analysis was conducted by measuring the greatest pelvic tilt angle in transverse plane and its reliability was assessed by use of the intraclass correlation coefficient (ICC); the mean change, which was evaluated using 95% confidence interval of the mean difference (95%CI ) and Bland-Altman plot; and the quantification of measurement variability, which was assessed using standard error of measurement (SEM) and the coefficient of variation of the typical error (CV TE). In addition, the minimal detectable change (MDC95) was determined. RESULTS: The intra-rater reliability ranged from fair to moderate (k w=0.32 to 0.58) and the inter-rater reliability was substantial (k w=0.80). The intra-test reliability was excellent (ICC=0.82), the 95% CI ranged from -0.51º to 1.99º, the SEM was 2.38º and the CV TE was 28.75%. The MDC95 was 6.59º. CONCLUSIONS: The inter-rater reliability was greater than the intra-rater reliability; the intra-test reliability was excellent and showed no systematic or random error.


Subject(s)
Female , Humans , Young Adult , Body Weights and Measures/methods , Knee Joint/physiology , Pelvis/anatomy & histology , Physical Examination/methods , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL